Front, top, side and section views
In an orthographic view every edge that lies in the plane of the view is drawn at its true length. A section is the same: a cut face seen square-on. Elevations and plans of a building are orthographic views too.
Open a scan, a screenshot or an exported image of the drawing. Click the two ends of one dimension that is written on it and type its value. Every length, hole and angle you draw after that reads in real units — including the ones the drafter did not dimension.
A drawing is not one picture at one scale. Each view shows true sizes only for the faces that are parallel to it.
In an orthographic view every edge that lies in the plane of the view is drawn at its true length. A section is the same: a cut face seen square-on. Elevations and plans of a building are orthographic views too.
A face tilted to the view is drawn shorter along the slope. A round hole in such a face is drawn as an ellipse, and only the ellipse's long axis is the true diameter. If the drawing has an auxiliary view looking square at that face, measure there.
In a true isometric projection lengths along the three axes are drawn at 0.82 of their size; many drawings skip the reduction and draw them full size, a difference of 22 % that the picture does not tell you. Lines off the axes are not to any scale, right angles are drawn at 60° and 120°, and circles are ellipses.
| Tilt of the face | Drawn length | Multiply the reading by |
|---|---|---|
| 15° | 97 % | 1.04 |
| 30° | 87 % | 1.15 |
| 45° | 71 % | 1.41 |
| 60° | 50 % | 2 |
A roof plan shows the footprint; the roof surface is larger by the factor in the table — 1.12 for a 6-in-12 pitch (about 27°). An elevation shows the rise, and not the rafter's length.
A sheet often carries more than one scale. The main views are at 1:2; "DETAIL A" beside them is at 2:1; a site plan sits next to a 1:20 section. The title block names only the main scale, and each of the others is written under its own view.
One image has one calibration. Calibrate on the main view and measure inside the detail, and every size comes out wrong by the ratio of the two scales: a 6 mm groove in a 2:1 detail, measured with a 1:2 calibration, comes out four times too large, as 24 mm.
So calibrate where you measure. The reference dimension has to be inside the view you are measuring — a dimension written in the detail, for the detail.
When a small feature has a detail view, measure it there. On a 200 dpi scan of a 1:2 drawing one pixel is 0.25 mm of the part; in the 2:1 detail of the same scan it is 0.06 mm.
A new calibration re-scales everything already drawn, including the shapes in the first view. Two ways to keep them apart:
Finish one view and write its results down before you recalibrate on the next.
Create the project from the sheet, duplicate it once for each further scale, and calibrate each copy on a dimension inside its own view. Each copy is a project of its own and counts as one.
A long shaft, beam or pipe is often drawn shortened: two wavy or zigzag break lines, and the middle left out. The written length is the real one; the drawn length is not. Never calibrate on a dimension that spans a break, and never measure across one. On either side of the break the view is still true.
A dimension with a straight line under its number is marked "not to scale": the value was changed in a revision and the geometry was not redrawn. The number is right and the picture is not. Do not calibrate on it, and distrust what you measure next to it.
Not to scale: schematics, piping and wiring diagrams, many catalog sketches. Nothing measured on such an image means anything.
A reference dimension — derived from the others, given for information, often rounded. Fine for a check, second-best as the calibration reference.
One more: a view of a symmetrical part may show only half of it, ending on a centerline. What you measure across it is half the part.
A drawing is made of lines with a width, and an image is made of pixels with a size. Both set a floor under every measurement, before your clicks add anything.
Drawings use a few standard widths: 0.5 or 0.7 mm for visible outlines, half of that — 0.25 or 0.35 mm — for dimension, extension and center lines. On the part or the building, the line covers its width times the scale:
| Scale | A 0.25 mm line covers | A 0.5 mm line covers |
|---|---|---|
| 1:2 | 0.5 mm | 1 mm |
| 1:10 | 2.5 mm | 5 mm |
| 1:50 | 12.5 mm | 25 mm |
| 1:100 | 25 mm | 50 mm |
The edge the drafter meant is the middle of the line. Click one line on its outer side and the other on its inner side, and a 3 m wall on a 1:50 drawing changes by up to 5 cm — almost 2 %. Zoom in until the line is several pixels wide and click its middle, the same way at both ends.
One pixel of a scan covers 25.4 mm ÷ dpi of paper, times the scale:
| Scan | On paper | At 1:2 | At 1:10 | At 1:50 | At 1:100 |
|---|---|---|---|---|---|
| 150 dpi | 0.17 mm | 0.34 mm | 1.7 mm | 8.5 mm | 17 mm |
| 300 dpi | 0.08 mm | 0.17 mm | 0.8 mm | 4 mm | 8.5 mm |
| 600 dpi | 0.04 mm | 0.08 mm | 0.4 mm | 2 mm | 4 mm |
At 150 dpi a 0.25 mm line is a pixel and a half wide — you cannot find its middle. At 300 dpi it is 3 pixels, at 600 dpi 6. For anything with fine lines, 300 dpi is the working minimum.
Count on about one pixel at each end of whatever you draw. On a 300 dpi scan of a 1:2 drawing that is about ±0.3 mm on any length, long or short — a small share of 240 mm, a large share of a 3 mm chamfer. On a 1:100 elevation at the same resolution it is about ±17 mm.
On a phone, press and hold to place a point under a magnified strip instead of under your fingertip.
It describes the sheet the drawing was plotted on; a scan, a reduced print or a screenshot has a size of its own. Measure floor plans shows what printing and scanning do to it. The ratio still tells you which views share a scale.
An overall length beats a hole spacing, and a hole spacing beats a diameter. The clicks cost the same pixel or two either way; on a long reference they are a smaller share.
Click where the dimension line meets its extension lines — the arrow tips or the ticks. That is what the number refers to.
For 240 ±0.5, type 240. For a dual-dimensioned drawing, 240 [9.449], pick one system and stay in it.
Site plans and maps often carry one: click its two ends and type the length written on it. A new project in a free account can read a bar with a metric label by itself and open already calibrated; the value is applied as read, not verified, so look at the baseline before you measure.
In the same view, at a right angle to the first if there is one. Old copiers and some scanners stretch a sheet slightly more one way than the other. If lengths across the sheet agree and lengths down it are all off by the same percent, calibrate along the direction that matters most.
The Angle tool needs no calibration. A corner that should be 90° and reads 88° or 92° means the sheet was photographed at a slant or the scan is skewed — rescan it, or shoot it flat from directly above. A plain rotation is harmless: lengths do not change when the whole sheet is turned.
A crooked scan can be straightened with Crop & rotate; applying it clears the calibration and every measurement, so it comes first. A drawing photographed at an angle that cannot be rescanned can be calibrated with Perspective PRO in a saved project, from a rectangle whose width and height are both written on the drawing. It measures only inside that rectangle, and without the Circle tool.
A scan, a screenshot at high zoom, or a page exported from a PDF. A crooked scan: straighten it with Crop & rotate first.
Pick the Calibration tool, click the two ends of the longest dimension in the view, type its value and pick its unit — millimeter under Metric, inch under Imperial.
Open Settings and switch off Automatic unit conversion. Every length then stays in the unit you calibrated in; with it on, 160 mm reads as 16 cm and 30 in as 2.5 ft.
Draw a Line along another written dimension in the same view and compare.
A Line for a length, a Circle for a hole, the Angle tool for a chamfer or a bend, a Polygon for an outline's area and perimeter. Click a label for the full details. Measurements are black by default and vanish into black linework: give their layers a color in Layers.
The drawing: a steel plate, 10 mm thick, drawn at 1:2 on A3, with one corner cut and two holes on the centerline. It gives the overall size, 240 × 120, and the hole diameter. It does not give the hole spacing or the size of the cut corner. A 2:1 detail shows a groove on the lower edge, 6 wide, depth not given.
One pixel of the scan is about a quarter of a millimeter of plate. Automatic unit conversion is off; Rounding is set to one decimal for lengths and none for areas and angles.
Two pixels of doubt on each length is 0.5 mm. That settles the spacing as 160 and the cut as 40 × 40, and it tells a 22 mm hole from a 21 or a 24 — the fine and coarse clearance holes for the same M20 bolt. It would not tell 22.0 from 22.3. The traced outline is 0.1 % over the area the drawing's own numbers give.
| What | Reading | Doubt |
|---|---|---|
| Groove depth | 2.5 mm | about ±0.1 mm |
| The same depth, measured in the main view | 2.5 mm | about ±0.5 mm — a fifth of the value |
C1 — 383 mm²
General| What | How | Reading | On the drawing |
|---|---|---|---|
| Height, as a check | Line along the dimension | 120.1 mm | 120 |
| Hole spacing | Line, center cross to center cross | 160.0 mm | not given |
| Hole | Circle across the diameter; the label shows the area, d is in its details | d 22.1 mm | ⌀22 |
| Cut corner, each leg | Line | 39.9 mm | not given |
| Cut corner, angle | The Angles tab in the outline's details | 135° inside — a 45° cut | not given |
| Outline | Polygon, five corners | A 28,036 mm², P 696.9 mm | 28,000 and 697 by calculation |
For a flat part cut from sheet or plate, two numbers price it: how much material, and how far the cutter travels. A Polygon around the outline gives both.
The plate above, by the drawing's numbers: 28,000 mm² is 280 cm².
280 cm² × 1 cm × 7.85 g/cm³ = 2.2 kg
Holes are not part of the outline, so take them out by hand: two ⌀22 holes are about 7.6 cm², which leaves 2.14 kg. The same plate in aluminum, at 2.70 g/cm³: 0.74 kg.
Here the holes are under 3 % of the weight. On a perforated or heavily slotted part they are the answer; measure each opening as its own Circle or Polygon and subtract.
Outline 697 mm, plus two holes of 69 mm around each:
697 mm + 2 × 69 mm = 835 mm
835 mm of cut.
A curved outline is followed by a Polygon with short straight sides; more corners, less error. The Curve area tool PRO draws a smooth outline instead.
| Material | Density |
|---|---|
| Steel | 7.85 g/cm³ |
| Stainless steel (304) | 7.9–8.0 g/cm³ |
| Aluminum | 2.70 g/cm³ |
| Brass | about 8.5 g/cm³ |
| Acrylic | 1.18 g/cm³ |
Calibrate in inches with Automatic unit conversion off, and every length stays in inches and every area in square inches; with it on, anything a foot or longer reads in feet. Readings are decimal: 2⅜″ reads 2.375 in with Rounding set to three decimals for lengths. The same unit family has the mil — a thousandth of an inch — for small features.
To calibrate on a dimension written in feet, inches and fractions, type it as a decimal:
2′-6⅜″ = 2 × 12 + 6 + 0.375 = 30.375 in
A reading of 0.37 or 0.38 on a fractional drawing is 3⁄8: such drawings are made in sixteenths or thirty-seconds, so round to the nearest one the reading can support.
| Fraction | Decimal inch | Millimeters |
|---|---|---|
| 1⁄16 | 0.0625 | 1.6 |
| 1⁄8 | 0.125 | 3.2 |
| 1⁄4 | 0.25 | 6.4 |
| 3⁄8 | 0.375 | 9.5 |
| 1⁄2 | 0.5 | 12.7 |
| 5⁄8 | 0.625 | 15.9 |
| 3⁄4 | 0.75 | 19.1 |
| 7⁄8 | 0.875 | 22.2 |
Amplia measures images, so a PDF page becomes one first.
From your PDF viewer, as PNG; JPEG smears thin lines. A PDF plotted from drawing software is vector: a large sheet can be exported at 300 dpi and an A3 or smaller at 600, with every line sharp. A PDF that is a scan holds one picture at the scanner's resolution, and exporting it larger adds pixels, not detail. Info → Image shows the pixel size you got; at 300 dpi it should be:
| Sheet | At 300 dpi |
|---|---|
| A4 | about 3,500 × 2,500 px |
| A3 | about 5,000 × 3,500 px |
| A1 | about 9,900 × 7,000 px |
| ARCH D, 24 × 36 in | 10,800 × 7,200 px |
With a PRO plan, a new project can be created from a PDF: pick the file and type the page number.
A screenshot is the weak route. A whole A1 sheet on a full-HD screen spreads 841 mm over about 1,900 pixels: one pixel is almost half a millimeter of paper, over 2 cm of building at 1:50, and the thin lines are gone. Zoom until the view you need fills the screen before you take it.
The guest workspace opens such an image as it is. A project on the free plan holds images up to 10 MB and offers to compress a larger one to JPEG at the same pixel size, so the measurements stay where they are.
The general tolerances most metric part drawings call up are of the same size as the image's own doubt, or smaller. A reading good to ±0.3 mm can say which size a feature was meant to be. It cannot say whether a part is in tolerance, and it cannot define one.
If you have the CAD file, the program that made it reads exact sizes from the model. An image is for when the file is gone.
Not a sloped face, an isometric view, anything across a break line or anything marked not to scale.
| Nominal size | ISO 2768 fine | ISO 2768 medium | ISO 2768 coarse |
|---|---|---|---|
| over 6 to 30 mm | ±0.1 | ±0.2 | ±0.5 |
| over 30 to 120 mm | ±0.15 | ±0.3 | ±0.8 |
| over 120 to 400 mm | ±0.2 | ±0.5 | ±1.2 |
| over 400 to 1,000 mm | ±0.3 | ±0.8 | ±2 |
Rooms and floor area have their own page: Measure floor plans.
You can, and you should know what the note means: where a dimension is missing or unclear, the author decides, not a ruler. Use the measured value for an estimate or to ask a precise question. Do not make a part or set out a building from it.
Something whose real size you know. A feature of standard size drawn in the view — a door leaf, a brick course, a column grid. Or the sheet itself, when the scan shows the whole sheet at the size the title block names: the long edge of an A3 is 420 mm, which at 1:50 is 21 m. An A3 printed on A4 breaks that. Both are weaker than a written dimension; say so beside the number.
If its center is marked, draw a Line from the center cross to the arc. If it is not, measure the chord c between the arc's ends and the rise h from the middle of the chord to the arc: R = c² ⁄ (8h) + h ⁄ 2. A chord of 40 and a rise of 5 give 42.5. The rise is the short one, so its doubt decides: half a millimeter on that rise moves the radius by about 4 mm. Use the longest chord the arc allows.
Read the callout — M10, ⅜-16. The picture of a thread is a convention: a thick line on the crests, a thin line on the roots, and the gap between them drawn to be visible, not to the thread's depth. On a tapped hole seen end-on, the thick circle is the smaller, minor diameter; the nominal size is the thin three-quarter circle around it. Measuring that one can tell an M10 from an M12. The pitch is not drawn at all.
Open the drawing, mark one size that is written on it, and measure the one that is not.
Open the free tool